GP 33 series 10-200kva
Product Features
--Advanced DSP digital control technique
ShangYu GP33 series adopts advanced DSP digital control technique, while promoting the performance of the product at the same time, it greatly satisfy the user’s demand to power supply products’ practicality,
high efficiency, reliability and safety. Although electricity environment is relatively poor, it can ensure stable run continuously.
--N+X parallel redundancy(support parallel machine sharing battery)
GP33 series of 10-200 k product can support 4 set of UPS parallel machine which is suitable for using in the N + X redundant applications. In the redundant work condition, the system can share a set of batteries saving the investment cost of users.
--Excellent industrial environmental protection performance
Under standard configuration it can meet IP21 protection grade.But in order to achieve higher dustproof requirements, the user can choose dust components to improve dustproof level under industrial environment, ensuring the UPS equipment can operate safely under the harsh environment.
Providing a wide range of input voltage 285 vac - 475 vac can apply to bad power grid environment, excellent input frequency range make UPS can adapt different power supply devices, such as generator.
--Positive operations and maintenance functions
Give full consideration to the effective utilization of user space;Modular design and the positive maintenance, greatly shorten the troubleshooting time of the machine, improve the availability of the UPS system.
GP33 series of 10-200 kva UPS has compact structure which meet the requirements of users, and it adopts the built-in battery design which can achieve positive maintenance replacement battery, at the same time ,it cover an area of an area small and saves valuable space.
--Overload capacity
110%< load ≤125% , greater than or equal to 10 minutes transfer to the bypass.
125%< load ≤150% , greater than or equal to 1 minutes transfer to the bypass.
--Reliability, Flexibility, Economy
--Advanced DSP digital control technique
ShangYu GP33 series adopts advanced DSP digital control technique, while promoting the performance of the product at the same time, it greatly satisfy the user’s demand to power supply products’ practicality,
high efficiency, reliability and safety. Although electricity environment is relatively poor, it can ensure stable run continuously.
--N+X parallel redundancy(support parallel machine sharing battery)
GP33 series of 10-200 k product can support 4 set of UPS parallel machine which is suitable for using in the N + X redundant applications. In the redundant work condition, the system can share a set of batteries saving the investment cost of users.
--Excellent industrial environmental protection performance
Under standard configuration it can meet IP21 protection grade.But in order to achieve higher dustproof requirements, the user can choose dust components to improve dustproof level under industrial environment, ensuring the UPS equipment can operate safely under the harsh environment.
Providing a wide range of input voltage 285 vac - 475 vac can apply to bad power grid environment, excellent input frequency range make UPS can adapt different power supply devices, such as generator.
--Positive operations and maintenance functions
Give full consideration to the effective utilization of user space;Modular design and the positive maintenance, greatly shorten the troubleshooting time of the machine, improve the availability of the UPS system.
GP33 series of 10-200 kva UPS has compact structure which meet the requirements of users, and it adopts the built-in battery design which can achieve positive maintenance replacement battery, at the same time ,it cover an area of an area small and saves valuable space.
--Overload capacity
110%< load ≤125% , greater than or equal to 10 minutes transfer to the bypass.
125%< load ≤150% , greater than or equal to 1 minutes transfer to the bypass.
--Reliability, Flexibility, Economy
In order to improve the precision, accuracy and stability of the GP33 series 10-200 kva system control, in the control system, using DSP and CPU, DSP with the ability of the highly effective operation, after signal processing, providing CPU as system control. Powerful operation ability makes the system control ability faster and more accurate, which is beneficial to enhance the system's reliable digital control system, simplify the peripheral control circuit, reduce the use of traditional analog components, avoid analog components of zero drift problem happens after running for a long time.It enhance the stability of the system control, especially benefit to reliable operation of the parallel machine system.
--Clear and simple operation of the LCD panel in both Chinese and English
GP33 series 10-200kva adopts large screen LCD graphical display panel in both Chinese and English which convenient to operate for users
--Intelligent charging management
Advanced intelligent charging ways through the control of CPU,According to the different environmental conditions, UPS charger can fixed charge parameters and provide a optimized way to battery charge.
--Efficient and energy saving
The machine efficiency is as high as 92%;Under the ECO mode,the machine efficiency is as high as 98% which reduces the UPS power loss.
Intelligent high-frequency inverter technology, the input power factor is as high as 0.99, input current harmonic is less than 3%.
--Abundant monitoring and communication interface
GP33 series of 10-200kva UPS provides Intelligent Slot , expansion Slot, the PARALLEL, EXT.BATTERY TEMP PROBE、AS400、EPO、RS485、RS232 and SERVICE monitoring communication interface which is our company or our company authorized technical personnel dedicated.
Technical Parameters
Model | GP3310K | GP3315K | GP3320K | GP3330K | GP3340K | GP3360K | GP3380K | GP33100K | GP33120K | GP33160K | GP33200K | |
CAPACITY | 10 KVA / 8 KW | 15 KVA / 12 KW | 20 KVA / 16 KW | 30 KVA / 24 KW | 40 KVA / 32 KW | 60 KVA / 48 KW | 80 KVA / 64 KW | 100 KVA / 80 KW | 120 KVA / 96 KW | 160 KVA / 128 KW | 200 KVA / 160 KW | |
INPUT | ||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Acceptable Voltage Range | 285VAC ~ 475VAC | |||||||||||
Frequency | 50/60 Hz ± 10 % | |||||||||||
INVERTER | ||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Precision | Stationary: ±1% ; Transitory: ±5% (load variations 100-0-100%) | |||||||||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz | |||||||||||
Max. Synchronisation Speed | ±1 Hz/s | |||||||||||
Waveform | Pure Sinewave | |||||||||||
Total Harmonic Distortion (THDv) | < 2% (Linear Load) ; < 5% (Non-linear Load) | |||||||||||
Phase Displacement | 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) | |||||||||||
Dynamic Recovery Time | 3 cycles at 90 % of the static value | |||||||||||
Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | |||||||||||
Admissible Crest Factor | 3:01 | |||||||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||||||||
Imbalance Output Voltage @ 100% Unbalanced Loadt | <1% | |||||||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit | |||||||||||
STATIC BYPASS | ||||||||||||
Type | Solid state | |||||||||||
Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Frequency | 50/60 Hz | |||||||||||
Activation Criterion | Microprocessor control | |||||||||||
Transfer Time | Zero | |||||||||||
Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | |||||||||||
Transfer to Bypass | Immediate, for overloads above 160% | |||||||||||
Retransfer | Automatic after alarm clear | |||||||||||
MAINTENANCE BYPASS | ||||||||||||
Type | Without interruption | |||||||||||
Voltage | 3 x 400V (3Ph + N) | |||||||||||
Frequency | 50/60 Hz | |||||||||||
Overall Efficiency (Line mode) | Line Mode | 89% | 90% | 91% | 92% | |||||||
Battery Mode | 90% | 91% | 92% | 93% | ||||||||
BATTERY & CHARGER | ||||||||||||
Battery Type and Numbers | 12VDC x 32 pcs (29~32 pcs adjustable) | |||||||||||
Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) | |||||||||||
Charging Method | CC/CV | |||||||||||
Charging Current | Default 10A, Max. = Capacity(KW) / Battery Voltage (real-time) | Default: 10A. Max. 40A; 5A@ full load | ||||||||||
Charging Voltage | 432 VDC (Based on 32pcs batteries) | |||||||||||
PHYSICAL | ||||||||||||
Dimension, D x W x H (mm) | 656 x 405 x 817 | 656 x 405 x 941 | 821 x 432 x 1159 | 975 x 554 x 1286 | 975 x 554 x 1326 | 1051 x 705 x 1646 | ||||||
Net Weight (kgs) | 118 | 120 | 145 | 193 | 278 | 365 | 471 | 573 | 650 | 760 | 840 |